← Back to both Savi LoopIQ Labs
Savi LoopIQ • Learning library

Take the lesson with you

Download a free reflection and repetition worksheet for each verified native exercise. These files are learning companions, not graded answer keys or certificates. The original ChatGPT-hosted 84-case simulator is preserved separately; this collection covers only the exercises that can be verified from the native LoopIQ source.

Public practice (60)

Choose a case to print or save a PDF study sheet; editable plain-text worksheets remain available.

Flow 02 — small clean bump

The synthetic case is identifiable, but students should learn that an undersized field bump can be buried by real measurement noise and disturbances.

Print / save as PDF →Editable text ↓
Flow 03 — downward output step

Students see that process gain comes from the relationship between delta PV and delta OP, not from assuming every bump is positive.

Print / save as PDF →Editable text ↓
Flow 04 — light transmitter noise

The identifier should remain stable, while the student learns to inspect signal-to-noise evidence instead of assuming every trend is equally trustworthy.

Print / save as PDF →Editable text ↓
Temperature 01 — basic thermal loop

Introduce slower thermal time constants and show why the same tuning aggressiveness should not be copied across loop types.

Print / save as PDF →Editable text ↓
Temperature 02 — clear large step

A larger excitation improves identifiability in the presence of ordinary measurement resolution, while real plants still require safe operating limits.

Print / save as PDF →Editable text ↓
Level 02 — low process gain

Students learn to separate slow dynamics from low process gain; they are different model parameters with different tuning consequences.

Print / save as PDF →Editable text ↓
Level 03 — trend stops before full settle

A model may be computable without the test being ideal. Students should notice the unsettled flag and extend the window when possible.

Print / save as PDF →Editable text ↓
Level 04 — OP moved, PV did not

Possible causes include the wrong tag, blocked actuator, insufficient test authority, or a failed measurement. LoopIQ should not invent a model.

Print / save as PDF →Editable text ↓
Pressure 07 — oscillation overlaid on response

Students should recognize that a simple FOPDT fit can be useful while still missing an oscillatory mechanism that deserves separate diagnosis.

Print / save as PDF →Editable text ↓
Temperature 05 — slow thermal loop

Slow thermal processes punish aggressive tuning; compare the baseline against the recommended rule and inspect settling and robustness.

Print / save as PDF →Editable text ↓
Pressure 11 — late disturbance during test

Students should recognize that disturbances can bias steady-state estimates even when the initial step response is sound.

Print / save as PDF →Editable text ↓
Pressure 12 — wrong or blocked PV

The application should force investigation of tag selection, actuator response, or process connectivity before any tuning work continues.

Print / save as PDF →Editable text ↓
Temperature 09 — high-gain slow thermal loop

Students should see why slow does not automatically mean low sensitivity; gain and time constant must be considered separately.

Print / save as PDF →Editable text ↓
Temperature 10 — reverse-acting thermal process

Sign handling must remain correct even on slow delayed loops where a wrong action assumption would be especially costly.

Print / save as PDF →Editable text ↓
Temperature 11 — thermal drift during bump

Students should treat nonstationary tests cautiously because apparent process gain can include background heat-balance movement.

Print / save as PDF →Editable text ↓
Level 10 — reverse-acting inventory response

The case connects process configuration to controller action: outlet valves commonly invert the sign relative to inlet manipulation.

Print / save as PDF →Editable text ↓
Level 11 — coarse sampling and partial settle

The model may remain usable for study, but the combined evidence quality should trigger explicit engineering review.

Print / save as PDF →Editable text ↓
Level 12 — capture ends before useful response

Students should learn to size the historian window from expected process dynamics rather than a fixed clock duration.

Print / save as PDF →Editable text ↓
Analyzer 12 — noisy signal below SNR floor

The correct result is a quantitative refusal, preserving the distinction between visual pattern matching and defensible identification.

Print / save as PDF →Editable text ↓

Angel graded lab (23)

Choose a case to print or save a PDF study sheet; editable plain-text worksheets remain available.

Advanced control practical (8)

Choose a case to print or save a PDF study sheet; editable plain-text worksheets remain available.

L4 design challenge (8)

Choose a case to print or save a PDF study sheet; editable plain-text worksheets remain available.

Competency review (12)

Choose a case to print or save a PDF study sheet; editable plain-text worksheets remain available.

These worksheets do not grant controller access. Use the in-app assessment engine for actual proficiency and credential decisions. Live process changes always require site authorization.